6,188 research outputs found

    Optimization of an Electromagnetic Energy Harvesting Device

    No full text
    This paper presents the modeling and optimization of an electromagnetic-based generator for generating power from ambient vibrations. Basic equations describing such generators are presented and the conditions for maximum power generation are described. Two-centimeter scale prototype generators, which consist of magnets suspended on a beam vibrating relative to a coil, have been built and tested. The measured power and modeled results are compared. It is shown that the experimental results confirm the optimization theory

    A comparative study of angle dependent magnetoresistance in [001] and [110] La2/3Sr1/3MnO3La_{2/3}Sr_{1/3}MnO_3

    Full text link
    The angle dependent magnetoresistance study on [001] and [110] La2/3_{2 / 3}Sr1/3_{1 / 3}MnO3_{3} thin films show that the anisotropy energy of [110] films is higher when compared with a [001] oriented La2/3_{2 / 3}Sr1/3_{1 / 3}MnO3_{3} film of similar thickness. The data has been analyzed in the light of multidomain model and it is seen that this model correctly explains the observed behavior.Comment: 8pages, 2 figure

    Microelectromechanical systems vibration powered electromagnetic generator for wireless sensor applications

    No full text
    This paper presents a silicon microgenerator, fabricated using standard silicon micromachining techniques, which converts external ambient vibrations into electrical energy. Power is generated by an electromagnetic transduction mechanism with static magnets positioned on either side of a moving coil, which is located on a silicon structure designed to resonate laterally in the plane of the chip. The volume of this device is approximately 100 mm3. ANSYS finite element analysis (FEA) has been used to determine the optimum geometry for the microgenerator. Electromagnetic FEA simulations using Ansoft’s Maxwell 3D software have been performed to determine the voltage generated from a single beam generator design. The predicted voltage levels of 0.7–4.15 V can be generated for a two-pole arrangement by tuning the damping factor to achieve maximum displacement for a given input excitation. Experimental results from the microgenerator demonstrate a maximum power output of 104 nW for 0.4g (g=9.81 m s1) input acceleration at 1.615 kHz. Other frequencies can be achieved by employing different geometries or material

    Fiber-Flux Diffusion Density for White Matter Tracts Analysis: Application to Mild Anomalies Localization in Contact Sports Players

    Full text link
    We present the concept of fiber-flux density for locally quantifying white matter (WM) fiber bundles. By combining scalar diffusivity measures (e.g., fractional anisotropy) with fiber-flux measurements, we define new local descriptors called Fiber-Flux Diffusion Density (FFDD) vectors. Applying each descriptor throughout fiber bundles allows along-tract coupling of a specific diffusion measure with geometrical properties, such as fiber orientation and coherence. A key step in the proposed framework is the construction of an FFDD dissimilarity measure for sub-voxel alignment of fiber bundles, based on the fast marching method (FMM). The obtained aligned WM tract-profiles enable meaningful inter-subject comparisons and group-wise statistical analysis. We demonstrate our method using two different datasets of contact sports players. Along-tract pairwise comparison as well as group-wise analysis, with respect to non-player healthy controls, reveal significant and spatially-consistent FFDD anomalies. Comparing our method with along-tract FA analysis shows improved sensitivity to subtle structural anomalies in football players over standard FA measurements

    Critically phase-matched Ti:sapphire-laserpumped deep-infrared femtosecond optical parametric oscillator based on CdSiP2

    Get PDF
    We report a high-repetition-rate femtosecond optical parametric oscillator (OPO) for the deep-infrared (deep-IR) based on type-I critical phase-matching in CdSiP2 (CSP), pumped directly by a Ti:sapphire laser. Using angle-tuning in the CSP crystal, the OPO can be continuously tuned across 7306–8329 nm (1201–1369  cm−1) in the deep-IR. It delivers up to 18 mW of idler average power at 7306 nm and >7  mW beyond 8000 nm at 80.5 MHz repetition rate, with the spectra exhibiting bandwidths of >150  nm across the tuning range. Moreover, the signal is tunable across 1128–1150 nm in the near-infrared, providing up to 35 mW of average power in ∼266  fs pulses at 1150 nm. Both beams exhibit single-peak Gaussian distribution in TEM00 spatial profile. With an equivalent spectral brightness of ∼5.6×1020photons s−1 mm−2 sr−10.1% BW−1, this OPO represents a viable alternative to synchrotron and supercontinuum sources for deep-IR applications in spectroscopy, metrology, and medical diagnostics.Peer ReviewedPostprint (author's final draft

    Femtosecond deep-infrared optical parametric oscillator pumped directly by a Ti:sapphire laser

    Get PDF
    We report a high-repetition-rate femtosecond optical parametric oscillator (OPO) for the deep-infrared (deep-IR) based on the nonlinear optical crystal, CdSiP2 (CSP), pumped directly by a Ti:sapphire laser, for the first time. By pumping CSP at <1 μm, we have achieved practical output powers at the longest wavelengths generated by any Ti:sapphire-pumped OPO. Using a combination of pump wavelength tuning, type-I critical phase-matching, and cavity delay tuning, we have generated continuously tunable radiation across 6654−8373 nm (1194−1503 cm-1) at 80.5 MHz repetition rate, providing up to 20 mW of average power at 7314 nm and <7 mW beyond 8000 nm, with idler spectra exhibiting bandwidths of 140−180 nm across the tuning range. Moreover, the near-IR signal is tunable across 1127−1192 nm, providing up to 37 mW of average power at 1150 nm. Signal pulses, characterised using intensity autocorrelation, have durations of ∼260–320 fs, with corresponding time-bandwidth product of ∆υ∆τ∼1. The idler and signal output exhibit a TEM00 spatial profile with single-peak Gaussian distribution. With an equivalent spectral brightness of ∼6.68×1020 photons s-1 mm-2 sr-1 0.1% BW-1, this OPO represents a viable table-top alternative to synchrotron and supercontinuum sources for deep-IR applications in spectroscopy, metrology and medical diagnostics.Peer ReviewedPostprint (author's final draft

    Quantum matchgate computations and linear threshold gates

    Full text link
    The theory of matchgates is of interest in various areas in physics and computer science. Matchgates occur in e.g. the study of fermions and spin chains, in the theory of holographic algorithms and in several recent works in quantum computation. In this paper we completely characterize the class of boolean functions computable by unitary two-qubit matchgate circuits with some probability of success. We show that this class precisely coincides with that of the linear threshold gates. The latter is a fundamental family which appears in several fields, such as the study of neural networks. Using the above characterization, we further show that the power of matchgate circuits is surprisingly trivial in those cases where the computation is to succeed with high probability. In particular, the only functions that are matchgate-computable with success probability greater than 3/4 are functions depending on only a single bit of the input

    Fluoride-containing bioactive glasses: Effect of glass design and structure on degradation, pH and apatite formation in simulated body fluid

    Get PDF
    NOTICE: this is the author’s version of a work that was accepted for publication in Acta Biomaterialia. Changes resulting from the publishing process, such as peer review, editing, corrections, structural formatting, and other quality control mechanisms may not be reflected in this document. Changes may have been made to this work since it was submitted for publication. A definitive version was subsequently published in Acta Biomaterialia, [VOL 6, ISSUE 8, (2010)] DOI: 10.1016/j.actbio.2010.01.04
    corecore